F12.02
Parameter locking
0: do not lock
1: reference input not locked
2: all locked, except for this
function code
0
F12.09
Load speed display
coefficient
0.01~600.00
30.00
F12.10
UP/DOWN
acceleration and
deceleration rate
0.00: automatic rate
0.01~500.00
Hz/s
5.00
F12.11
Options of
UP/DOWN offset
clearing
0: do not clear
1: clear in non-running state
2: clear when UP/DOWN invalid
0
F12.12
Options of
UP/DOWN
power-down saving
of offset
0: do not save
1: save (valid after the offset is
modified)
1
F12.13
Power meter resetting
0: do not clear
1: clear
0
F12.14
Restoration of default
setting
0: No operation
1: restoration of factory defaults
(excluding the motor parameters,
inverter parameters, manufacturer
parameters, running and power-on
time record)
0
F12.15
Cumulative power-on
time h
0~65,535
h
XXX
×
F12.16
Cumulative power-on
time min
0~59
min
XXX
×
F12.17
Cumulative running
time
0~65,535
h
XXX
×
F12.18
Cumulative running
time (min)
0~59
min
XXX
×
F12.19
Rated power of
inverter
0.40~650.00
kW
Dependi
ng on
the
motor
type
×
F12.20
Rated voltage of
inverter
60~690
V
Dependi
ng on
the
×

Table of Contents