User Manual of A90 Series Inverter
104
Torque current
integral time constant
ACR-T2
0.00-600.00
0.00: no integral
SVC zero-frequency
processing
0: braking
1: not processed
2: seal the tube
SVC zero-frequency
braking current
50.0-400.0 (100.0 is the no-load
current of the motor)
SVC low-frequency
excitation current
50.0-150.0 (100.0 is the no-load
current of the motor)
Acceleration/decelera
tion time options of
motor 2
0: the same as motor 1
1: acceleration and deceleration
time 1
2: acceleration and deceleration
time 2
3: acceleration and deceleration
time 3
4: acceleration and deceleration
time 4
Maximum frequency
of motor 2
Upper frequency limit
of motor 2
Lower limit frequency F00.19 to
maximum frequency F14.78
V/F curve setting of
motor 2
0: straight line V/F
1: multi-point broken line V/F
Multi-point VF
frequency F1 of
motor 2
Multi-point VF
voltage V1 of motor 2
0.0~100.0 (100.0 = Rated voltage)
Multi-point VF
frequency F2 of
motor 2
Multi-point VF
voltage V2 of motor 2
Multi-point VF
frequency F3 of
motor 2
F14.83 to rated frequency of
motor (reference frequency)