User Manual of A90 Series Inverter
107
0: running after power-on
1: running at startup
2: intelligent operation, subject to
temperature control
Deceleration time for
quick stop
0.00 - 650.00 (F15.13=0)
0.0 - 6500.0 (F15.13=1)
0 - 65000 (F15.13=2)
Power-frequency load
factor
Customization function group
0: general model
1: air compressor application
2: extruder application
3: water pump application
4: fan application
1 - 65535 (F16.13=0)
0.1 - 6553.5 (F16.13=1)
0.01 - 655.35 (F16.13=2)
0.001 - 65.535 (F16.13=3)
Set time of regular
running
Setting of cumulative
power-on arrival time
0-65535; 0: disable the protection
when the power-on time is up
Setting of cumulative
running arrival time
0-65535; 0: disable the protection
when the running time is up
Analog output
percentage
corresponding to the
count value 0