User Manual of A90 Series Inverter
38
3.3.1
Composition of control circuit terminal
Fig. 3-11 Layout of Control Circuit Terminals
3.3.2
Functions and wiring of control circuit terminals
Table 3-4 Functions of Control Circuit Terminals
Type
Terminal
label
Terminal name
Terminal function description
Auxiliary
power
supply
10V-GND
+10V power
supply
Supply +10V power to external devices.
Maximum output current: 20mA
24V-COM
1)
+24V power
supply
Supply +24V power to external devices. It is
usually used as the working power supply for
digital input and output terminals and also the
power supply for external devices. Maximum
output current: 100mA
Analog
input
AI1-GND
Analog input
terminal 1
Input voltage range: DC 0-10V; input
impedance: 1MΩ
AI2-GND
Analog input
terminal 2
Input range: DC 0-10V/0-20mA. The
voltage/current mode is selected via the switch
S2 on the control panel.
Input impedance: 1MΩ in the voltage mode
and 250Ω in the current mode
Digital
input port
X1-COM
1)
Multi-function
input terminal 1
Common terminal: COM
Input impedance: 5.1
Y1
X1 X2 X3 X4 X5
24V
AI1 AI2 M1 A+ A-GND10V
COM
M2
RJ45
EA EB EC
V
AI2
I
S2
OFF
485
ON
S1
KeyBoard
8 1