EasyManua.ls Logo

Sinee A90-4T5R6B - Page 68

Sinee A90-4T5R6B
300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual of A90 Series Inverter
68
2: valid 2
F00.25
Noise suppression of
carrier frequency
0: Invalid
1: valid
0
F00.26
Noise suppression
tone
20~200
Hz
40
F00.27
Noise suppression
intensity
10~150
Hz
0
F00.28
Options of motor
parameter group
0: parameter group of motor 1
1: parameter group of motor 2
0
F00.29
User password
0~65,535
0
F00.30
Inverter type
0: heavy-duty
1: light-duty
0
F01
Parameter group of motor 1
F01.00
Motor type
0: ordinary asynchronous motor
1: variable-frequency
asynchronous motor
2: permanent magnet synchronous
motor
0
F01.01
Rated power of
electric motor
0.10~650.00
kW
Model
Confirm
F01.02
Rated voltage of
motor
50~2,000
V
Model
Confirm
F01.03
Rated current of
motor
0.01 to 600.00 (rated power of
motor: ≤ 75 kW)
0.1 to 6,000.0 (rated power of
motor: > 75 kW)
A
Model
Confirm
F01.04
Rated frequency of
motor
0.01~600.00
Hz
Model
Confirm
F01.05
Rated speed
1~60,000
rpm
Model
Confirm
F01.06
Motor winding
connection
0: Y
1: Δ
Model
Confirm
F01.07
Rated power factor of
motor
0.600~1.000
Model
Confirm
F01.08
Motor efficiency
30.0~100.0
%
Model
Confirm
F01.09
Stator resistance of
asynchronous motor
1-60,000 (rated power of motor: ≤
75 kW)
0.1-6,000.0 (rated power of
motor: > 75kW)
mΩ
Model
Confirm
F01.10
Rotor resistance of
asynchronous motor
1-60,000 (rated power of motor: ≤
75 kW)
mΩ
Model
Confirm

Table of Contents

Related product manuals