User Manual of A90 Series Inverter
87
Simple PLC memory
options
Ones place:
Stop memory options
0: no memory (from the first
segment)
1: memory (from the moment of
stop)
Tens place:
Power-down memory
options
0: no memory (from the first
segment)
1: Memory (from the power-down
moment)
0: s (second)
1: min (minute)
Setting of the first
segment
Ones place:
Running direction
options
0: forward
1: reverse
Tens place:
Acceleration and
deceleration time options
0: acceleration and deceleration
time 1
1: acceleration and deceleration
time 2
2: acceleration and deceleration
time 3
3: acceleration and deceleration
time 4
Running time of the
first segment
Setting of the second
segment
Ones place:
Running direction
options
0: forward
1: reverse
Tens place:
Acceleration and
deceleration time options
0: acceleration and deceleration
time 1
1: acceleration and deceleration
time 2
2: acceleration and deceleration
time 3