14
Service Manual
Removal:
1. Remove face plate cover and arm top cover.
2. Remove needle by loosing the screw (B) with thread guide, the screw (A) and needle bar
gib (C).
3. Loosen needle threader bight stop screw (D) (For models with Needle threader) and
needle bar clamping screw (E).
4. Draw needle bar (F) up and out of the machine.
Replacement:
1. Replacement is the same as removal in reverse order.
2. Then, adjust needle bar height (see pages 67-68).
Needle Bar
P/N 358426002
MAR/05
Rev. no.