14. Cut Engine remotely
Cut Engine command: 940+password
Sample: 9400000
After tracker receive command, it will cut engine and send back SET OK
Recover Engine command: 941+password
After tracker receive command, it will recover engine and send back “SET OK”
15. Set APN
Command : 803+password+Blank+APN
Sample: 8030000 CMNET
Reply: SET OK
If your APN need user and pass:
Command : 803+password+Blank+APN+Blank+APNuser+Blank+APNpass
Sample: 8030000 CMNET CMNET CMNET
Reply: SET OK
16. Set the IP and Port
Command: 804+password+Blank+IP+Blank+Port
Sample: 8040000 45.112.204.242 8090
Reply: SET OK
17. Set the time interval
ACC on time interval (default is 20 seconds)
Command: 805+password+Blank+T
Sample: 8050000 20
Reply: SET OK
T means the time interval, the unit is second,
It from 0 to 18000 seconds,
When T=0 means close GPRS.
ACC off time interval (default is 300 seconds)
Command: 809+password+Blank+T
Sample: 8090000 300
Reply: SET OK
T means the time interval, the unit is second,
It from 0 to 18000 seconds,
When T=0 means close GPRS.
The minimum time interval is 10 seconds.