B. STEP TWO - MIXING OF POWDER (HOMOGENISATION)
To ensure that both types of powders mix thoroughly (both in the rst and second method), we recommend sieving them
2-3 times to obtain a homogeneous blend.
1. Take out from Drawer 3 and place the Funnel on the Metal container. Remember to put a clamping ring between the
Funnel and the Metal Container.
2. Turn on the vacuum cleaner (from „0” to „1”). Vacuum Suction sensor indicator
22
should light up.
3. Press the ON/OFF Sifting button
14
to turn on the Sifting Module
11
and the Powder Feeding Screw
23
.
4. On the Control panel, in the SUCTION section, the LED above the DEPOWDERING ZONE
17
should be activated.
5. Gently pour the entire content of the Metal container onto the Powder Chamber grid
1
. Remember not to pour the
powder on the grid of the Fine Dust Chamber
2
- there must be access to the air!
6. After emptying the Powder Chamber and sifting the powder, remove the Metal container from the Sifting module
and put a new one in its place.
7. To ensure homogeneous mixing of the powders, repeat steps 1-6 at least once more.
8. The newly created powder (Print Ready Powder) is mixed and ready to use in the Sinterit Lisa/Lisa PRO printer.
PRE-
PRINT
READY
POWDER
PRINT
READY
POWDER
1. CONNECT METAL CONTAINER
WITH POWDER TO THE FUNNEL
2. POUR THE POWDER INTO CHAMBER
TO MIX IT BY THE PHS SYSTEM
Image. 42. Process of mixing of both powders (Pre-Print Ready) - powder homogenization.
POWDER HANDLING STATION Manual | 30