Pilot flame ignition
Depress the button and ignite the pilot flame,
keeping the button fully depressed for a few seconds
(fig.1). In controls with enabling for electrical
ignition, the pilot can be ignited automatically by
depressing the button . Release the knob and
check that the pilot flame stays lit. If it goes out,
repeat the ignition operation.
Main burner ignition
Depress the transverse button (fig.2) (manual
versions).
The gas passage to the main burner is opened by
powering the automatic solenoid valve.
The valve with step ignition device reaches the
maximum flow after about 10 seconds.
Pilot flame ignition
Fully depress the knob (fig.1) to keep the main
burner closed and the pilot flame lit.
Shutdown
Fully depress the knob (fig.3).
CAUTION: the restart interlock device prevents igni-
tion of the appliance until the flame failure device has
stopped gas flow. At the end of this period (after clo-
sing the magnet unit) it is possible to carry out the
re-ignition operation.
OPERATION
fig. 1
fig. 2
fig. 3