OPERATION
PRODUCT SPECIFICATIONS:
SMOKE ALARM USER MANUAL
PHOTOELECTRIC SMOKE ALARM GS528A-MG
Testing: Test weekly by pushing the test button on the cover and holding it down for a minimum of 5 seconds.
this will sound the alarm if the electronic circuitry, horn, and battery are working properly.
DO NOT use an open flame to test your alarm, you could damage the alarm or ignite combustible materials and
start a structure fire.
CAUTION: Due to the loudness (85 decibels) of the alarm, Always stand an arms-length away from the unit
when testing. Test the alarm weekly to ensure proper operation. Erratic or low sound coming from your alarm
may indicate a defective alarm.
LED indicators: This smoke alarm is equipped with red LED indicators.
Standby Condition: The red LED will flash every 32 seconds to indicate that the smoke alarm is operating properly.
Alarm Condition: When the alarm senses products of combustion and goes into alarm, the red LED will flash
rapidly (one flash per second).The rapid flashing LED and pulsating alarm will continue until the air is cleared
or the test button is released.
Power:
Operaon Current:
Sensor Type:
Alarm Volume:
DC 9V baery
<11uA(standby), <30mA (alarm)
Photoelectric
>85dB(A) at 3 meters
Low baery warning:
Averssement de baerie faible:
Alarm Sensivity:
Comply With:
6.5-7.8V
6.5-7.8V
1.51-2.64%/ OBS
UL217 &CAN/ULC-S531
GS528A-MG
Question and Answer IconNeed help?

Do you have a question about the Siterwell GS528A-MG and is the answer not in the manual?

Siterwell GS528A-MG Specifications

General IconGeneral
Sensor TechnologyPhotoelectric
Test ButtonYes
Low Battery IndicatorYes
Wireless Frequency433MHz
CertificationEN 14604
Alarm Volume≥85dB at 3 meters
Operating Temperature0°C ~ 40°C
Operating Humidity10% ~ 90%RH non-condensing
Wireless Range100m (open area)
Silence Duration10 minutes

Summary

Product Specifications

Operation

Testing Procedure

Test weekly by pushing the test button for at least 5 seconds to ensure alarm functionality.

LED Indicators

Describes red LED flashes for standby (every 32s) and alarm (rapidly) conditions.

Installation Notes

Ceiling Mounting

Locate alarm on ceiling at least 4" (10cm) from side wall.

Wall Mounting

Use inside wall, top edge 4"-12" (10-30.5cm) below ceiling.

Hallway & Room Placement

Place alarms at both ends of hallways/rooms over 30 ft (9.1m) long.

Sloped/Peaked Ceiling Placement

Install within 3 ft (0.9m) of highest point, on high side for slopes > 1:8.