28
5
E²ROM ERROR
- E²ROM cannot read and write
Normal
running
6
Refrigerator
defrosting
ERROR
- When the refrigerator defrost 40 minutes, it will
automatically stop.
Normal
running
7
Cycle ERROR
- The COMP continuously run 30 minutes.
The temperature of D-SENSOR doesn’t reach 0℃
Normal
running(freeze
r)
3-5. PCB function instructionDry–type model ( REF / FRE)
Model
Sensor
Compressor
HTR
Front PCB
Memo
R-
Sensor
D-Sensor
1Comp
2Comp
R/F
DUAL
SUR/F 9-1
O
O
O
O
O
SGR9-1
SUR/F12-2
O
O
O
O
O
SGR12-2
SUR/F15-2
O
O
O
O
O
SGR15-2
SUR/F18-3
O
O
O
O
O
SGR18-3
SHR9-1
O
O
O
O
O
SGR9-1
SHR12-2
O
O
O
O
O
SSR12-2
SHR15-2
O
O
O
O
O
SSR15-2
SHR18-3
O
O
O
O
O
SSR18-3
3-6. COMPRESSOR running、starting、stopping
3-6-1. COMP running
- COMP will stop for 4 minutes. (When the comp stopped, comp will be banned running during the
4 minutes.)

Table of Contents