EasyManua.ls Logo

Sky Climber Compact 1250 - Air Motor Troubleshooting

Default Icon
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
January 2019 Page 17
TROUBLESHOOTING (Continued)
POSSIBLE PROBLEMS WITH AIR MOTOR
Low
Torque
Low
Speed
Won't
Run
Runs
Hot
Runs
Well
Then
Slows
Down
REASON & REMEDY
FOR PROBLEM
Dirt or foreign material present.
Inspect and flush.
Internal rust.
Inspect and flush.
Low air pressure.
Increase air pressure.
Air line too small.
Install larger line(s).
Restricted exhaust.
Inspect and repair.
Motor is jammed.
Have motor serviced.
Air source inadequate.
Inspect and repair.
Air source too far from motor.
Reconfigure setup.