Section 1 - Scheduled Maintenance Operator’s Responsibility for Maintenance
WARNING
Failure to comply with your required responsibilities in the use and operation of the aerial platform
could result in death or serious injury!
Operator Safety Reminders
A study conducted by St. Paul Travelers showed that most accidents are caused by the failure of the operator to
follow simple and fundamental safety rules and precautions.
You, as a careful operator, are the best insurance against an accident. Therefore, proper usage of this aerial platform
is mandatory. The following pages of this manual should be read and understood completely before operating the
aerial platform.
Common sense dictates the use of protective clothing when working on or near machinery. Use appropriate safety
devices to protect your eyes, ears, hands, feet and body.
Any modifications from the original design are strictly forbidden without written permission from SKYJACK Inc.
Electrocution Hazard
This aerial platform is not electrically insulated. Maintain a Minimum Safe Approach Distance (MSAD) from energized
power lines and parts as listed below. The operator must allow for the platform to sway, rock or sag. This aerial
platform does not provide protection from contact with or proximity to an electrically charged conductor.
DO NOT USE AERIAL PLATFORM AS A GROUND FOR WELDING.
DO NOT OPERATE AERIAL PLATFORM DURING LIGHTNING OR STORMS.
CE Guidance Note
“Avoidance of danger from overhead lines”
Voltage Range Minimum Safe Approach Distance
(Phase to Phase) (Feet)
0 to 300V Avoid Contact
Over 300V to 50KV 10
Over 50KV to 200KV 15
Over 200KV to 350KV 20
Over 350KV to 500KV 25
Over 500KV to 750KV 35
Over 750KV to 1000KV 45
60023AD
DANGER
FAILURE TO AVOID THIS HAZARD WILL RESULT IN DEATH OR SERIOUS INJURY!
Avoid Power Lines
Minimum Safe Approach Distance
ANSI/SIA A92.6-2006
and CSA B354.2-01 Requirements
Adhere strictly to the governmental rulings
and regulations applicable in your country.

Table of Contents

Other manuals for Skyjack SJ 4620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ 4620 and is the answer not in the manual?

Skyjack SJ 4620 Specifications

General IconGeneral
BrandSkyjack
ModelSJ 4620
CategoryBoom Lifts
LanguageEnglish

Related product manuals