MODEL EH ELECTRIC BOILER
EH-08-135-S2 through EH-40-135-S2, single phase, 3 wire, 120/208V, 120/240V
EH-12-345-S2 through EH-40-345-S2, three phase, 4 wire, 120/208V, 120/240V
OPERATION AND INSTALLATION INSTRUCTIONS
CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Air Eliminator and Expansion Tanks . . . . . . . . . . . . . . . . . .2
Flow Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Bypass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Wall Thermostat Flow Switch and Circulator . . . . . . . . . . .2
Typical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Service Connections and Electrical Ratings . . . . . . . . . . . .2
Rough-In Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Electrical Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Typical Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Typical Zone Valve Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Fill System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Air Elimination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Bypass Flow Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . .7
Check for Proper Boiler and System Operation . . . . . . . . .7
Operation (models equipped with seq. control system) . . . . . . .7
Periodic Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Appendix A, B, C & D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
IMPORTANT:
This manual must be left with owner and should be hung
on or adjacent to the boiler for reference.
Wiring diagram located on inside front panel.
S2
Heating Contractor
Address
Phone Number
Boiler Model Number
Boiler Serial Number
Installation Date
Part # 790920000 • Publication EH-40-S2 Rev A • Printed in U.S.A. 519

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Slant/Fin Monitron EH-20-135-S2 and is the answer not in the manual?

Slant/Fin Monitron EH-20-135-S2 Specifications

General IconGeneral
ModelEH-20-135-S2
CategoryBoiler
Fuel TypeElectric
Phase1
Heating Capacity135, 000 BTU
BTU Input135, 000 BTU
Voltage208/240V
Output BTU135, 000 BTU

Related product manuals