EasyManua.ls Logo

Sloan OPTIMA plus Series User Manual

Sloan OPTIMA plus Series
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Code No. 0816302
Rev. 3b (11/08)
INSTALLATION INSTRUCTIONS FOR
SENSOR ACTIVATED LAVATORY FAUCETS
LIMITED WARRANTY
Sloan Valve Company warrants its EBF-85 and EBF-187 Faucets to be made of first class materials, free from defects of material or workmanship under normal use and to perform the
service for which they are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years (1 year for special finishes) from date of
purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer's
cost, and this shall be the sole remedy available under this warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or
organizations who purchase Sloan Valve Company's products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the batteries (battery operated
models).
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES
OF ANY MEASURE WHATSOEVER.
PRIOR TO INSTALLATION
Prior to installing the Sloan EBF-85 or EBF-187 Faucet, install the items
listed below. Also, refer to the Rough-In illustrations on Page 2.
Lavatory/sink
Drain line
Hot and cold water supply lines or tempered water supply line
Mixing Valve
When installing the faucet with a Sloan mixing valve, these Installation
Instructions AND the Installation Instructions packaged with the mixing
valve MUST be followed.
Important:
INSTALL ALL PLUMBING IN ACCORDANCE WITH APPLICABLE CODES
AND REGULATIONS.
KEEP THREAD SEALANT OUT OF YOUR WATERWAY TO PREVENT
COMPONENT PART DAMAGE! DO NOT USE ANY SEALANT ON
COMPRESSION FITTINGS. FOR THREADED PIPE FITTINGS, DO NOT
APPLY SEALANT TO THE FIRST TWO “STARTER” THREADS.
FLUSH ALL WATER LINES UNTIL WATER IS CLEAR BEFORE CONNECTING
SOLENOID TO SUPPLY STOPS.
DO NOT INSTALL THE BATTERIES UNTIL THE FAUCET IS COMPLETELY
INSTALLED. If the batteries are installed before the fiber optic cable has
been connected to the valve module, the faucet will not properly set the
sensing range for the sink on which it is installed.
DO NOT INSTALL THE SPRAY HEAD UNTIL AFTER THE SUPPLY LINES
HAVE BEEN FLUSHED.
BAK-CHEK
®
TEE USAGE
When connecting the Sloan EBF-85 or EBF-187 Faucet to both hot and cold
water supplies, a Bak-Chek
®
Tee is provided and required as illustrated in
the Rough-in illustrations on Page 2. Water temperature can be controlled
by adjusting the supply stops.
When connecting the faucet to a single line water supply or a pre-tempered
water supply, a Bak-Chek
®
Tee is not required.
A Bak-Chek
®
Tee is not required or provided when a Temperature Mixing
Valve is included with the faucet.
TOOLS REQUIRED FOR INSTALLATION
Open end wrenches for hex sizes: 1/2”, 9/16”, 5/8”, 15/16”
Basin wrench
Phillips head screwdriver, #2
Hammer (if installing plastic or hollow wall anchors to mount valve
module)
0.05” hex wrench (supplied)
Spray head key (supplied)
1/4” drill bit (if plastic wall anchors are used to mount valve module)
5/16” drill bit (if hollow wall anchors are used to mount valve module)
3/8” drill bit (if toggle nut anchors are used to mount valve module)
Model EBF-85
Battery Powered, Sensor Activated Lavatory Faucet
Furnished with a Black Plastic Throat Plate
Model EBF-187
Battery Powered, Sensor Activated Lavatory Faucet
Furnished with a Chrome Plated Metal Throat Plate
Compliant to: ASME A112.18.1
and CSA B125.1
Question and Answer IconNeed help?

Do you have a question about the Sloan OPTIMA plus Series and is the answer not in the manual?

Sloan OPTIMA plus Series Specifications

General IconGeneral
BrandSloan
ModelOPTIMA plus Series
CategoryPlumbing Product
LanguageEnglish

Summary

Installation Preparation and Tools

Prior to Installation

Prepare lavatory, drain line, and water supply lines before faucet installation.

Important Installation Notes

Follow plumbing codes, avoid sealant in waterways, flush lines before connecting.

Tools Required

Lists necessary tools like wrenches, screwdrivers, and drill bits for installation.

Faucet Assembly and Rough-In

Faucet Rough-In Diagrams

Diagrams illustrating rough-in configurations for different supply and mixing valve setups.

Install Faucet Spout and Trim Plate

Step-by-step guide for assembling the faucet spout and trim plate onto the sink deck.

Plumbing and Electrical Connections

Install Valve Module Wall Bracket

Instructions for mounting the valve module bracket to the wall.

Connect Tubing to Spout

Connecting the water supply lines to the faucet spout.

Install Valve Module

Securing the valve module into its wall bracket.

Connect Tubing to Solenoid Valve and Fiber Optic Cable

Connecting water supply lines to the solenoid valve and attaching the fiber optic cable.

Connect Supply Lines to Solenoid Valve Inlet

Connecting hot/cold or single line water supply to the solenoid valve inlet.

Install Batteries

Inserting batteries into the battery compartment for power.

Operation, Maintenance, and Troubleshooting

Start Up and Self-Calibration

Explains adaptive sensing and the automatic self-calibration procedure upon power-up.

Test Faucet Operation

Describes how the sensor activates water flow and automatic shut-off.

Battery Replacement

Step-by-step guide for replacing the faucet's batteries.

Solenoid Filter Cleaning

Procedure for cleaning the solenoid screen filter to ensure proper water flow.

Troubleshooting Guide

Lists common problems, causes, and solutions for faucet operation issues.

Care and Cleaning

Guidelines for cleaning faucet finishes without causing damage.

Related product manuals