6 Connection
SMA Solar Technology AG
Installation ManualMDSEN-US-40-IA-en-1320
2. On the 5-pole terminal block, unlock the terminal
position 1 using a suitable tool ( ) and plug the
conductor of the cable piece for shielding into this
terminal position ( ).
3. For connection to the module using two-conductor connection technology, perform the
following steps:
• On the 5-pole terminal block, unlock the terminal positions 3 and 4 using a suitable tool
and plug the conductors of the connection cable into these terminal positions. Observe
the pin assignment.
• On the 5-pole terminal block, bridge the
terminal positions 2 and 3 as well as the
terminal positions 4 and 5.
4. For connection to the module using four-conductor connection technology, unlock the terminal
positions 2, 3, 4, and 5 on the 5-pole terminal block using a suitable tool and plug the
conductors of the connection cable into these terminal positions. Observe the pin assignment.
5. To connect the outside temperature sensor, plug the 5-pole terminal block into pin row A on
terminal TEMP-IN.
6. To connect the module temperature sensor, plug the 5-pole terminal block into pin row B on
terminal TEMP-IN.
7. If no further connections are required on the module or in the inverter, close the inverter and
commission it (see the inverter manual).
8. If necessary, configure the temperature sensor (see Section7.2, page26).
6.5 Connecting an Irradiation Sensor
You can connect a maximum of 1 irradiation sensor to the module.
Additionally required material (not included in the scope of delivery):
☐ 1 irradiation sensor
☐ 1 connection cable (see Section6.1, page15)
Requirements:
☐ The irradiation sensor must be technically suitable for connection to the analog input (see
Section9, page31).
☐ The connection cable must be prepared for connection to the multipole terminal block (see
Section6.2, page15).