EasyManua.ls Logo

SMA SOLID-Q 50 - Read Input Register (Function Code: 0 x04); Request Frame Structure; Response Frame Structure; Error Response Structure

SMA SOLID-Q 50
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMA New Energy Technology (Jiangsu) Co., Ltd.
15 SMASOLID-Q-Modbus-TI-en-10 | Version 1.0 Technical Information
3.8.2 Read Input Register (Function Code: 0x04)
Request:
Device ID
1 Byte
Function code
1 Byte
Register Address(Hi)
1 Byte
Register Address(Lo)
1 Byte
Register length
2 Byte
CRC(Lo)
1 Byte
CRC(Hi)
1 Byte
Response:
Device ID
1 Byte
Function code
1 Byte
Byte count
1 Byte
Data
N × 1 Byte
CRC(Lo)
1 Byte
CRC(Hi)
1 Byte
Error
Device ID
1 Byte
Function code + 0x80
1 Byte
Exception code
1 Byte
CRC(Lo)
1 Byte
CRC(Hi)
1 Byte