18 SMASOLID-Q-Modbus-TI-en-10 | Version 1.0 Technical Information
3.8.5 Write Holding Multiple Registers (Function Code: 0x10) for
broadcast
Request:
Device ID
1 Byte
Function code
1 Byte
Register Address(Hi)
1 Byte
Register Address(Lo)
1 Byte
Register length
2 Byte
Data length
1 Byte
Data
N × 1Byte
CRC(Lo)
1 Byte
CRC(Hi)
1 Byte
Response: none
3.8.6 Exception Codes
0x01 Illegal function
0x02 Illegal address
0x03 Illegal data
0x04 Slave device failure