DIAGRAM POWER DISPLAY
MEASUREMENT ACCURACY
DANGER!
Electric shock caused by high voltage in the inverter.
Even when no external voltage is present, there can still be high voltages in the device.
The following work may be carried out by quali󹻭ed personnel only:
Electrical installation
Repairs
Modi󹻭cation
CAUTION!
Risk of injury from touching the enclosure during operation.
Burns to the body.
Only touch lid and display during operation.
NOTICE!
Yield loss due to poor heat dissipation!
Do not place objects on the enclosure.
Green LED is on: In operation
Green LED is 󹻮ashing: Waiting for su󹻯cient irradiation.
Red LED is on: Disturbance: contact installer.
Blue LED is on: The inverter has been incorporated into a Bluetooth network and can
communicate with other devices with identical NetID.
Blue LED is 󹻮ashing: The inverter was identi󹻭ed via Sunny Explorer by setting the "Find device"
parameter.
The power and energy of the inverter are displayed in three 󹻭elds: Power, Day and Total. The
display is updated every 󹻭ve seconds.
Power
The power that the inverter is currently feeding into the grid.
Day
The energy fed into the grid on this particular day. This equals the
energy generated between the inverter's start-up in the morning to the
current time.
Total
The total energy which the inverter has fed into the grid during its entire
operating time.
The inverter energy is shown as a diagram on the display. The
daily graph is displayed by default. The right-hand 󹻮ashing bar
of the diagram represents the current hour. If the inverter does
not feed any power to the grid over a longer period of time (e.g.
in darkness or if the PV modules are covered with snow), a gap
is inserted into the chart. The bar for the current hour is updated
automatically every 󹻭ve seconds.
After four seconds, the bar goes out for one second and then
displays the current value.
The display values may deviate from the actual values and must not be used as a basis for invoicing.
The inverter's measured values are required for the system management and to control the current to
be fed to the grid. The inverter does not have a calibrated meter.
GRAPHIC DISPLAY
SAFETY PRECAUTIONS PRODUCT OVERVIEW
Upper enclosure lid
Lower enclosure lid
Graphic display
Electronic Solar Switch
LEDs
Serial number
Identi󹻭cation of the Sunny Boy by the type label
SYSTEM OVERVIEW
Current output
Daily energy
Total energy generated since the inverter was installed
Text line for displaying an event
Graphical display of the inverter energy
The display updates the values of your PV system every 5 seconds.
Tapping on the cover:
• Activates the background illumination
• Switches from the energy values of the past 16 feed-in
hours to the daily energy values of the past 16 days
• Switches to the next text line
Disturbance
Contact installer
Switch open: no feeding-in
Switch closed: feeding-in
Grid voltage/current
Bluetooth connection to other devices
PV voltage/current
Grid event number
PV generator event number
Inverter event number
Power reduction due to excessive temperature
Clean the fan
Provide better ventilation for the inverter
Switches between inputs A and B
every 10 seconds
(applies only to Sunny Boy 4000TL /
5000TL)
LED