SMA Sunny Boy Series Specifications

General IconGeneral
CategoryInverter
Operating temperature range-25 °C to +60 °C
Protection DegreeIP65
AC Power OutputVaries by model
Number of MPP Trackers1 or 2, depending on the model
CoolingConvection
Warranty5 years standard, extendable

Summary

Information on this Document

Validity

Document describes connection options and operating modes for multifunction relay and OptiTrac Global Peak.

Target Group

Document is intended for users and installers; some tasks require electrically qualified persons.

Additional Information

Details on connection in installation manuals; further info at www.SMA.de/en.

Symbols Used

Explains safety symbols (DANGER, WARNING, CAUTION, NOTICE) and information icons.

Safety

Intended Use

Multifunction relay for switching loads; OptiTrac for performance optimization in shaded PV modules.

Safety Precautions

Details safety measures for high voltages, electrostatic discharge, and high contact loads.

Multifunction Relay

Possible Applications of the Multifunction Relay

Lists applications: fault indicator, self-consumption, load control, battery charging, fan control, grid feed-in.

Connection Options of the Multifunction Relay

Describes relay connections for fault indicator or load switching using different positions.

Connection as Fault Indicator Contact

Details wiring for indicating operation or error messages using the relay.

Connection for the Control of a Load

Explains connecting relay to control a load via contactor, with examples.

Connection for Grid Relay Switching Status

Connects multiple relays in parallel to signal grid operator about grid connection status.

Parameter Settings of the Multifunction Relay

Explains configuration of operating modes and settings via RS485 or Bluetooth.

Selecting the Operating Mode

Details selecting modes like Fault Indicator, Self-Consumption, Fan Control, etc.

Operating Mode: Error Message

How to use the relay as a fault indicator, displaying errors or undisturbed operation.

Operating Mode: Self-Consumption

Configuration for switching loads based on PV power and minimum duration.

Operating Mode: Fan Control

Automatic fan activation based on device temperature relative to derating thresholds.

Operating Mode: Control via Communication

Allows switching the relay via the inverter's communication interface.

Operating Mode: Charging the Battery

Controls battery charging based on minimum power thresholds and time delays.

Operating Mode: Switching Status Grid Relay

Relay switches simultaneously with the inverter's grid relay.

Technical Data of the Multifunction Relay

Provides specifications for switching voltage, current, terminals, and electrical endurance.

OptiTrac Global Peak

Activating the OptiTrac Global Peak

How to activate the function for improving PV system yield in shaded conditions.

Setting the OptiTrac Global Peak

Configuration of the interval for analyzing the PV array's operating point.

Contact