Do you have a question about the SMA Sunny Boy 6000US and is the answer not in the manual?
Model | Sunny Boy 6000US |
---|---|
Rated Output Power | 6000 W |
Maximum AC Power | 6000 W |
Maximum DC Voltage | 600 V |
Number of MPP Trackers | 2 |
Cooling | Convection |
Protection Class | IP65 |
Nominal AC Output Power | 6000 W |
Maximum AC Output Power | 6000 W |
Nominal AC Voltage | 240 V |
Nominal AC Frequency | 60 Hz |
Protection Degree | IP65 |
Type | Grid-tied inverter |
AC Voltage Range | 211 V - 264 V |
AC Frequency Range | 59.3 Hz - 60.5 Hz |
Operating Temperature Range | -25°C to +60°C |
Weight | 83.8 lbs (38 kg) |
Identifies qualified personnel as the intended audience for this installation guide.
Provides a general description of the Sunny Boy inverter and its function in a PV system.
Covers anti-islanding, ground fault detection, series fusing, and code compliance.
Gives a high-level summary of the manual's sections and installation process.
Lists all components included in the Sunny Boy and SMA DC-Disconnect packaging.
Step-by-step guide on how to open the Sunny Boy housing for configuration.
Illustrates and describes the locations of major internal components within the inverter.
Details how to reconfigure the inverter for different grid voltages (208V, 240V, 277V).
Explains the use and settings of configuration jumpers for various utility grid types.
Provides guidelines, cautions, and warnings for selecting an appropriate mounting location.
Specifies the inverter dimensions and required clearance for proper ventilation and installation.
Step-by-step instructions for mounting the wall bracket and the inverter itself.
Details the correct order for connecting AC and DC wires, with and without DC-Disconnect.
Covers AC connection requirements, wiring without and with SMA DC-Disconnect.
Covers DC connection requirements, grounding, and wiring without and with SMA DC-Disconnect.
Instructions for accessing the inverter and DC-disconnect components.
Step-by-step instructions for reassembling the inverter and DC-disconnect.
Explains the meaning of the green, red, and yellow LED status indicators during operation.
Describes fault conditions indicated by LED patterns, such as ground faults or fuse issues.
Details messages shown on the LCD display, including initialization, operation, and fault notifications.
Guides on how to configure the display language using slide switches.
Lists available measuring channels, parameters, and their abbreviations.
Provides initial steps for diagnosing and resolving operational issues with the inverter.
Lists error types, codes, and descriptions for diagnosing inverter faults.
Instructions for safely cleaning the inverter's internal cooling fans.
Details how to safely replace the GFDI fuse and PV string fuses.
States compliance with FCC rules regarding electromagnetic interference.
Provides visual diagrams for connecting the inverter to AC grids with and without a DC-disconnect.
Lists detailed technical specifications for Sunny Boy 5000US through 8000US models.
Defines grid voltage and frequency trip limits and associated trip times for protection.
Specifies recommended torque values and wire sizes for electrical connections.