IPC_STP-TI-en-14 | Version 1.4 ENGLISH
Reactive power is necessary for the stability of the utility grid. With the functions "Integrated Plant Control" and
"Q on Demand 24/7", it is possible that SMA inverters of type Sunny Tripower feed in reactive power during operation
and at night. The following table provides an overview of the device types and firmware versions for which the various
functions are available.
Device type Reactive power provision
0
overexcited
to 0
underexcited
Q on Demand 24/7 Integrated Plant Control
STP 15000TL-10/
STP 17000TL-10
from firmware version
2.60.02
from firmware version
2.60.02
from firmware version
2.62.04
STP 15000TLEE-10/
STP 20000TLEE-10
from firmware version
2.61.06
from firmware version
2.61.06
from firmware version
2.63.03
STP 20000TL-30/
STP 25000TL-30
from firmware version
2.80.04
from firmware version
2.82.03
from firmware version
2.82.03
Technical Information
Integrated Plant Control and Q on Demand 24/7
SUNNY TRIPOWER

Other manuals for SMA SUNNY TRIPOWER 20000TL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMA SUNNY TRIPOWER 20000TL and is the answer not in the manual?

SMA SUNNY TRIPOWER 20000TL Specifications

General IconGeneral
AC nominal power20000 W
Max. efficiency98.4%
Number of MPPTs2
Weight61 kg
Operating temperature range-25°C to +60°C
Max. input voltage1000 V
Rated AC power20000 W
Max. AC apparent power20000 VA
Max. output current29 A
AC grid frequency50 Hz / 60 Hz
Protection classIP65
CoolingOptiCool
Max. input current33 A
MPP voltage range420 V ... 800 V
Nominal AC voltage400 V
AC voltage range180 V ... 280 V