Smappee EV Wall Installation manual - English
11
Connectivity
Ethernet 100BASE-T
Communication protocol
OCPP 1.6 JSON, ready for update to OCPP 2.0
Certifications and Standards
Product certification
CE
Standards
IEC 61851-1 (2017)
Environment
Enclosure material
Steel (housing), aluminium (front plate)
Enclosure standard colours
RAL9016 (star white) + RAL7021 (black grey)
Protection degree
IP 54
Mechanical impact protection
IK10
Pollution degree
3
Electrical safety class
I
Stand-by use
LED brightness 0%: 2 W
LED brightness 100%: 5 W
Environmental conditions
Indoor and outdoor use
Operating temperature
-25 °C to 40 °C
Storage temperature
-25 °C to 60 °C
Relative humidity
0 % - 95 %, non-condensing
Maximum installation altitude
0 2.000 m
Access
Locations with restricted and non-restricted access
Physical properties
Dimensions
300 x 300 x 110 mm
Weight (excluding packaging)
6.2 kg
9.8 kg
Charging cable length
N/A
1 x 8 m
Supply line connection
Terminal block, flexible conductors up to 6 mm² or solid
conductors up to 10 mm²
Stationary / moveable
Fixed installation
External design
Enclosed assembly
Mounting method
Wall