AV L 2 0 - A
AV L 2 0 - 1 G A
Manual operation
with solenoid valve
Symbol
Description
Applicable size
AVL
2000
AVL
3000
AVL
4000
AVL
5000
❶
Body size 2 AVL2000 to 5000-A
● ● ● ●
+
❷
d
Rated coil
voltage
AC
(50/60Hz)
1 AC100V
● ● ● ●
2 AC200V
● ● ● ●
3 AC110V [AC115V]
*1
● ● ● ●
4 AC220V [AC230V]
*1
● ● ● ●
DC
5 DC24V
● ● ● ●
6 DC12V
● ● ● ●
+
❸
e
Electrical entry
D Type D(DIN terminal/With connector)
● ● ● ●
Y Type Y(DIN terminal/With connector)*
2
● ● ● ●
DO Type D(DIN terminal/Without connector)
● ● ● ●
YO Type Y(DIN terminal/Without connector)
● ● ● ●
M12 connector(Without cable)
〇
*3
〇
*3
〇
*3
〇
*3
+
❹
f
Light/
surge voltage suppressor
NIL None
● ● ● ●
With light/surge voltage suppressor
〇
*4
〇
*4
〇
*4
〇
*4
*1 The 110 VAC and 115 VAC are interchangeable. The 220 VAC and 230 VAC are interchangeable as well.
The allowable voltage fluctuation is -15% to +5% of the rated voltage for the 115 VAC or 230 VAC.
*2 Type “Y” is a DIN terminal conforming to EN-175301-803C (former DIN43650C).
*3 When the electrical entry is WO, rated coil voltage can be selected only DC(5,6).
*4 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected.
When it is WO, only for with light/surge suppressor can be selected.
-21-