EasyManua.ls Logo

SMC Networks AV2000-02-1 - Construction and Parts List; Component Overview and Parts

SMC Networks AV2000-02-1
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AV L 2 0 - A
AV L 2 0 - 1 G A
Manual operation
with solenoid valve
Symbol
Description
Applicable size
AVL
2000
AVL
3000
AVL
4000
AVL
5000
Body size 2 AVL2000 to 5000-A
d
Rated coil
voltage
AC
(50/60Hz)
1 AC100V
2 AC200V
3 AC110V [AC115V]
*1
4 AC220V [AC230V]
*1
DC
5 DC24V
6 DC12V
e
Electrical entry
D Type DDIN terminal/With connector
Y Type YDIN terminal/With connector*
2
DO Type DDIN terminal/Without connector
YO Type YDIN terminal/Without connector
WO
M12 connector(Without cable
*3
*3
*3
*3
f
Light/
surge voltage suppressor
NIL None
Z
With light/surge voltage suppressor
*4
*4
*4
*4
*1 The 110 VAC and 115 VAC are interchangeable. The 220 VAC and 230 VAC are interchangeable as well.
The allowable voltage fluctuation is -15% to +5% of the rated voltage for the 115 VAC or 230 VAC.
*2 Type “Y” is a DIN terminal conforming to EN-175301-803C former DIN43650C.
*3 When the electrical entry is WO, rated coil voltage can be selected only DC(5,6).
*4 When the electrical entry is DO or YO, light/surge voltage suppressor cannot be selected.
When it is WO, only for with light/surge suppressor can be selected.
-21-

Related product manuals