Page #94 background imageLoading...
Page #94 background image
-94-
No. DOC1045423
•Digital output unit (EX600-DY##)
Index
Name (Meaning)
Type
Value
40x0:0
Unit parameters
UNSIGNED8
19
40x0:02
Monitor short circuit (out)
Enum0800
0 = Disable
1 = Enable
40x0:06
Restart after short circuit
Enum0801
0 = Manual
1 = Auto
40x1:0
Monitor open circuit
UNSIGNED8
Number of Channels
40x1:01
:
40x1:18
Channel 0
:
Channel 23
Enum0800
0 = Disable
1 = Enable
40x2:0
Monitor counter limit
UNSIGNED8
Number of Channels
40x2:01
:
40x2:18
Channel 0
:
Channel 23
Enum0800
0 = Disable
1 = Enable
40x3:0
Counter limit value (1-65000K)
UNSIGNED8
Number of Channels
40x3:01
:
40x3:18
Channel 0
:
Channel 23
UNSIGNED16
1 to 65000
40x4:0
Fault mode
UNSIGNED8
Number of Channels
40x4:01
:
40x4:18
Channel 0
:
Channel 23
Enum0804
0 = Clear
1 = Hold
2 = ForceON
40x5:0
Idle mode
UNSIGNED8
Number of Channels
40x5:01
:
40x5:18
Channel 0
:
Channel 23
Enum0804
0 = Clear
1 = Hold
2 = ForceON
Note: x = Unit No.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks EX600-ED Series and is the answer not in the manual?

SMC Networks EX600-ED Series Specifications

General IconGeneral
BrandSMC Networks
ModelEX600-ED Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals