-75-
No.PS※※-OMV0006-D
Product individual parameters (continued)
Index
(dec)
Sub
index
Access
1
Parameter
Data
storage
2
Date
type
3
Initial value
(dec)
Remarks
0X07D4
(2004)
0 R
Diagnostic information
Number of
pressurizing
errors
N U16 0 0 ~ 1000
1: "R" means Read and "W" means Write.
2: "Y" indicates that the parameter setting data is saved to the master, and "N" indicates that the parameter is not saved.
3: Refer to the table below for the symbol.
Symbol
Data type
(IO-Link standard)
Data length
Bit [byte]
Description
U8
UIntegerT
8[1]
Unsigned integer
U16 16[2]
S16
IntegerT
16[2]
Signed integer
F32
Float32T
32[4]
Floating point number