EasyManua.ls Logo

Smeg A2-6 - Page 8

Smeg A2-6
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instructions for the installer
44
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31 28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.05 50 30 400 76 75
Semi rapid
1.8 65 33 500 131 129
Rapid
3 85 45 800 218 215
Triple crown
4.0 100 65 1600 290 286
Burner
Rated heating
capacity
(kW)
Natural gas – G20 20 mbar
Nozzle
diameter
1/100 mm
Reduced
flowrate
(W)
Auxiliary
1.05 72 400
Semi rapid
1.8 97 500
Rapid
3 115 800
Triple crown
4.0 135 1600
3.3 Arrangement of burners on cooking hob
BURNERS
1 Auxiliary
2 Semi rapid
3 Rapid
4 Ultra rapid
5 Ultra rapid