DISPLAYED MESSAGE POSSIBLE CAUSE REMEDY
PRESS OK TO START CLEANING
PROCESS OR TURN MILK
FROTH ADJUSTMENT KNOB
The milk container has been inserted
with the froth adjustment dial (D1) in the
CLEAN position .
To proceed with the CLEAN function, press
or turn the froth adjustment dial to one of the milk
positions.
TURN THE MILK FROTH ADJUST-
MENT KNOB TO START CLEANING
Milk has been delivered recently and the
tubes inside the milk container must be
cleaned (D).
Turn the froth adjustment dial (D1) to CLEAN
(g.21).
TURN THE MILK FROTH
ADJUSTMENT KNOB
TOMILKPOSITION
The milk container has been inserted
with the froth adjustment dial (D1) in the
CLEAN position.
Turn the dial to the required froth position.
DESCALING NEEDED
PRESS OK TO START
~45MIN
Indicates that the machine must be
de-scaled.
Press to start de-scaling or press
to de-scale later. The de-scaling procedure described
in section “De-scale” needs to be performed.
REPLACE WATER FILTER
PRESS OK TO START
The water softener lter (C4) is
exhausted.
Press to replace or remove the lter, or
to carry out the procedure later. Follow the
instructions in section “Water softener lter”.