Instructions for the installer
12
4. FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the
burner caps and the grids.
4.1 Adjustment of the hob burner minimum level for natural gas
Light the burner and take it to the minimum .
Remove the knob and turn the regulation screw
inside or next to the gas tap pin (depending on
the model) until you get a suitable minimum
flame.
Replace the knob and check burner flame
stability: (rapidly turning the knob from maximum
to minimum position, the flame should not go
out). Repeat the operation on all the gas taps.
4.2 Arrangement of the burners on the hob
Burners
1 Auxiliary
2 Semi rapid
3 Rapid
4 Wok