Instructions for the Installer
35
11.INSTALLING THE APPLIANCE
11.1 Electrical connection
Check that the power supply voltage and size are as specified on the nameplate on the oven door frame.
This nameplate must never be removed.
The appliance must be connected to earth in compliance with electrical system safety regulations.
If a socket and plug connection is used, check that they are of the same type. Do not use reducers,
adapters or junctions since they may cause overheating or burns.
If a permanent connection is used, the appliance's power supply line must be fitted with an omnipolar
breaking device with contact breaking gap of at least 3 mm, located in an easily accessible position
close to the appliance itself.
Operation at 220-240V~: use a H05RR-F / H05RN-F three-wire
cable (cable of 3 x 1.5 mm
2
).
The earth wire (yellow-green) must be at least 20 mm longer than
the other wires at the end for connection to the appliance.
The manufacturer declines all responsibility for injury or damage caused by failure to comply with the
above regulations or deriving from tampering with even just one part of the appliance.