RK cfk^i=lmbo^qflkp=
After replacing the nozzles, reposition the flame-spreader crowns, the
burner caps and the grids.
RKN ^ÇàìëíãÉåí=çÑ=íÜÉ=ÜçÄ=ÄìêåÉê=ãáåáãìã=äÉîÉä=Ñçê=å~íìê~ä=Ö~ë=
Light the burner and take it to the minimum .
Remove the gas tap knob and turn the
adjustment screw inside of the tap shaft
(depending on the model) until there is a regular
minimum flame. Replace the knob and check
burner flame stability: (rapidly turning the knob
from maximum to minimum position, the flame
should not go out). Repeat the operation on all
the gas taps.
=
RKO ^êê~åÖÉãÉåí= çÑ=íÜÉ=ÄìêåÉêë=çå=íÜÉ=ÜçÄ=
Burners
1 Auxiliary
2 Semi rapid
3 Rapid
4 Wok
7 Fish burner
=