SurgiVet® Universal CDS 9000
Small Animal Anesthesia Machine
Operation Manual
- English
Catalog Number WW V1932
Version 0, January 2009
©
2009 Smiths Medical family of companies. All rights reserved.
TM

Questions and Answers

  • J
    Justin ClarkAug 2, 2025
    How to fix no oxygen flow through oxygen flowmeter in Smiths Medical Equipment?
    • L
      Laurie WalkerAug 2, 2025
      If there is no oxygen flow through the oxygen flowmeter, several factors could be at play. First, ensure the oxygen tank isn't empty; if it is, use a full one. Also, verify that the oxygen tank is turned on. If the regulator is defective, press the Flush Valve to check if the machine is receiving oxygen. Check the oxygen hose to ensure it is properly connected and tightened at both the machine and the oxygen source. Finally, a damaged Needle Valve could be the culprit, requiring replacement.
  • L
    lawrencechaseAug 8, 2025
    What to do if patient does not respond to anesthetic agent with Smiths Medical Equipment?
    • L
      lisamooreAug 8, 2025
      If a patient isn't responding to the anesthetic agent, several factors should be investigated. Initially, check for leaks in the anesthesia machine by performing a Pressure Test using the Daily Machine checklist. Ensure that the oxygen flow is adequate, increasing it to at least 1 LPM. Verify that the vaporizer has an adequate amount of agent, filling it to the top fill line. Also, check for excessive draw or vacuum from the Active Waste Gas Scavenger, and reduce it if necessary. Lastly, check the service due date on the side of the vaporizer.
  • J
    jmaddoxAug 14, 2025
    Why rebreathing bag over inflates (Pressure is over 5 cm H O) 2 in Smiths Medical Equipment?
    • C
      caitlyn09Aug 14, 2025
      If the rebreathing bag over inflates, with pressure exceeding 5 cm H2O, several potential causes exist. First, the bag size might be inappropriate for the patient; check the bag size and replace it if necessary. The pop-off valve might be partially or completely closed or malfunctioning; ensure it is fully open. An obstruction in the Charcoal Canister could also be the issue; position it to allow proper gas flow. Lastly, a defective Flush Valve could be the cause, requiring inspection and replacement if needed.
  • E
    Erin BowmanAug 20, 2025
    How to troubleshoot when Smiths Medical Equipment fails Pressure Test on Daily Machine Checklist?
    • R
      randallhernandezAug 20, 2025
      If the machine fails the Pressure Test on the Daily Machine Checklist, it indicates a leak within the anesthesia machine. Begin by inspecting the absorber canister. Check for loose granules underneath the absorber gasket and ensure the vaporizer end caps are securely in place. Examine silicone hose connections for punctures, and inspect the bag and circuit hoses for any damage. Finally, verify that the vaporizer fill cap is tight.
  • C
    carlos09Aug 27, 2025
    Why rebreathing bag does not inflate in Smiths Medical Equipment?
    • M
      Miss Teresa PattersonAug 27, 2025
      If the rebreathing bag does not inflate, it may be due to a leak in the anesthesia machine; perform a Pressure Test using the Daily Machine checklist to identify any leaks. Another possible cause is excessive draw or vacuum from the Active Waste Gas Scavenger; decrease the amount of draw or vacuum to resolve this issue.

Summary

Chapter 1: Introduction

Warnings

Critical safety alerts and potential hazards associated with machine operation.

Chapter 3: Machine Operation

Set-up Diagram and Instructions

Step-by-step guide for assembling and preparing the anesthesia machine for use.

Chapter 4: Routine Maintenance

Daily Machine Checklist

Essential daily checks to ensure the machine is operating safely and effectively.

Pop-off Valve Removal and Cleaning

Detailed steps for removing, cleaning, and reassembling the pop-off valve.

Flowmeter Removal and Cleaning

Instructions for disassembling, cleaning, and reassembling the flowmeter.

Needle Valve Adjustment

Procedure for adjusting the needle valve to control gas flow.

Needle Valve Replacement

Steps for replacing the needle valve assembly for flow control.

Chapter 5: Troubleshooting

Troubleshooting Guide

Common problems, their causes, and corrective actions for the anesthesia machine.

Smiths Medical CDS 9000 Specifications

General IconGeneral
ManufacturerSmiths Medical
ModelCDS 9000
TypeInfusion Pump
Infusion ModesIntermittent
Volume Range0.1 to 9999 mL
Battery Life8 hours at 5 ml/hr
WeightApproximately 5.5 lbs (2.5 kg)
DisplayLCD
AlarmsOcclusion, Low battery, End of Infusion
CertificationsCE