7
ZCTR714ACE Rev. E (08/19)
Specifications
Square Drive Size ........................................... 1/4”
Motor Voltage ........................................14.4 VDC
Free Running Speed .......................350 RPM MAX
Torque Range ..........................35 ft. lbs. (47 N•m)
Weight with Battery Pack .............2.2 lbs. (1.0 kg)
Length ....................................10.75” (273.1 mm)
Height ..........................................3.3” (83.8 mm)
Width ............................................1.8” (45.7 mm)
Operating Temperature .........................................
................................. -4°F(-20°C) to 140°F(60°C)
Storage Temperature.............................................
................................. -4°F(-20°C) to 140°F(60°C)
CTR714A/CTRQ714
Noise* (Tested in accordance with ISO 15744)
Sound Pressure Level (A) .......................84.6 dB
Uncertainty, K ...........................................3.0 dB
Sound Power Level (A) ...........................96.2 dB
Uncertainty, K ...........................................3.0 dB
Vibration* (Tested in accordance with ISO 28927)
Vibration Level .....................................6.94 m/s
2
Uncertainty, K ......................................1.04 m/s
2
CTR717/CTRQ717
Noise* (Tested in accordance with ISO 15744)
Sound Pressure Level (A) .......................82.1 dB
Uncertainty, K ...........................................3.0 dB
Sound Power Level (A) ...........................93.7 dB
Uncertainty, K ...........................................3.0 dB
Vibration* (Tested in accordance with ISO 28927)
Vibration Level .....................................8.65 m/s
2
Uncertainty, K ......................................2.44 m/s
2
*These declared values were obtained by
laboratory type testing with the stated standards
and are not adequate for use in risk assessments.
Values measured in individual work places may be
higher. Values and risk of harm experienced by an
individual user are unique and depend upon the
environment and manner in which the user works,
the work piece and the workstation design, as well
as upon the exposure time and the physical
condition of the user.
We, Snap-on Tools Company, cannot be held liable
for the consequences of using the declared values,
instead of values reflecting the actual exposure
determined in an individual risk assessment in a
work place situation over which we have no control.
Symbology
SYMBOLOGY
REFER TO INSTRUCTION
MANUAL/BOOKLET
WEAR EYE PROTECTION
WEAR HEARING PROTECTION
VIBRATION HAZARD
VOLTS
DIRECT CURRENT
n
0
xxx/min NO LOAD SPEED
CE MARK
CANADIAN - UNITED STATES
UNDERWRITERS LABORATORY
FCC
FEDERAL COMMUNICATIONS
COMMISSION
JAPAN ELECTRICAL SAFETY
TÜV RHEINLAND
DOUBLE INSULATION
BACK FEED PROTECTION
PROPERLY RECYCLE BATTERY

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Snap-On CTR714A and is the answer not in the manual?

Snap-On CTR714A Specifications

General IconGeneral
BrandSnap-On
ModelCTR714A
CategoryPower Tool
LanguageEnglish