MINI USB PORT
*WARNING: ONLY USE THE MINI USB PORT IN AREAS KNOWN TO
BE NON-HAZARDOUS!
SENSOR INPUT — Accepts DE9P subminiature 9-pin male
connector. Sensors feature full bridge, 350 ohm, strain gages
and built-in EEPROM memory chip for range identification and
calibration. Sensor excitation is 3.3 volts DC. Gages are
sampled 3 times/second and always sampled at 320 times/seconds
when input exceed 1% of sensor range.
POWER SWITCH — Disconnects the AA battery source from the
VERSATORQ2 circuit. At power-on, unit comes to life, self-checks
and returns to last SET-UP parameters unless sensor has been
changed.
EARPHONE JACK — 1/8 inch diameter stereo tip jack, provides
two distinctive tones; a low tone at MIN preset torque input and a
high tone at or above MAX torque input. (Does not disable the
Alarm sounder when in use).
*WARNING: ONLY USE THE HEADPHONE PORT IN AREAS KNOWN
TO BE NON-HAZARDOUS!
AUDIBLE ALARM — Produces a distinctive 2 KHz continuous
tone at MIN preset torque input and a pulsating tone at or above
MAX torque input. Also sounds momentarily at each key pad entry.