Do you have a question about the Sofar 4000TLM-G2 and is the answer not in the manual?
Rated AC Power | 4000 W |
---|---|
Max. DC Power | 5200 W |
Max. DC Voltage | 600 V |
Start Voltage | 120V |
Number of MPPTs | 2 |
Max. AC Current | 18.2A |
AC Voltage Range | 180-280V |
AC Output Frequency | 50 Hz / 60 Hz |
THDi | <3% |
DC Connection | MC4 |
AC Connection | Screw terminal |
Protection Degree | IP65 |
Topology | Transformerless |
Cooling | Natural convection |
Peak Efficiency | 98.2% |
Rated AC Voltage | 230 V |
Rated Grid Frequency | 50 Hz |
Power Factor | 0.8 leading to 0.8 lagging |
Operating Temperature Range | -25°C to 60°C |
Provides essential safety instructions for installation and operation of the inverter.
Outlines the step-by-step process for installing the SOFAR 3K~6KTLM-G2 inverter.
Details the steps for physically mounting and securing the SOFAR 3K~6KTLM-G2 inverter on a wall.
Provides a flowchart for connecting various cables to the inverter.
Guides on connecting the DC input power cables, including cable specifications and preparation.
Details the process of connecting the AC output power cables to the inverter and AC breaker.
Outlines necessary safety checks before starting the inverter commissioning process.
Details the steps to safely start the inverter after commissioning checks are completed.
Provides procedures and information to identify and resolve common inverter faults and problems.