TROUBLESHOOTING HANDLING
HYD 5K...20KTL-3PH 121
ID147
BluetoothFault
Bluetooth error
Check the Bluetooth
connection of the inverter.
ID148
RTCFault
RTC clock failure
Internal error of the
inverter. Switch off the
inverter, wait 5 minutes
and then switch the unit
back on.
If the error persists,
contact technical support.
ID149
CommEEPROMFault
EEPROM error of
the communication
card
ID150
FlashFault
Communication
card FLASH error
ID152
SafetyVerFrauIt
ID153
SciCommLose(DC)
SCI communication
error (DC)
ID154
SciCommLose(AC)
SCI communication
error (AC)
ID155
SciCommLose(Fuse)
SCI communication
error (fuse)
ID156
SoftVerError
Inconsistent
software versions
Download the latest
firmware from the website
and launch the software
update. If the error
persists, contact technical
support.
ID157
BMSCommunicatonFault
(BMS 1)
Lithium battery
communication
error
Make sure your battery is
compatible with the
inverter.
CAN communication is
recommended. Check the
communication line or the
connection of the battery
and the inverter for errors.