Sofarsolar HYD 5KTL-3PH - User Manual

Sofarsolar HYD 5KTL-3PH
128 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HYD 5 20KTL-3PH
Installation and
operating manual
Version 01 | May 2022
English
HYD 5KTL-3PH, HYD 6KTL-3PH, HYD 8KTL-3PH, HYD 10KTL-3PH, HYD
15KTL-3PH, HYD 20KTL-3PH

Other manuals for Sofarsolar HYD 5KTL-3PH

Questions and Answers

  • J
    Jason HudsonAug 13, 2025
    How to fix FreqDerating on my Sofarsolar Inverter?
    • J
      James EnglishAug 14, 2025
      To resolve FreqDerating on your Sofarsolar Inverter, ensure that the grid frequency and voltage are within the acceptable range.
  • A
    Anna PalmerAug 17, 2025
    How to resolve PvConfigError on Sofarsolar HYD 5KTL-3PH?
    • R
      Rhonda FrancoAug 17, 2025
      To resolve a PvConfigError on your Sofarsolar Inverter, check the PV input mode settings (parallel/independent mode). If the settings are incorrect, change the PV input mode accordingly.
  • S
    Stephen LoganAug 21, 2025
    Why does my Sofarsolar HYD 5KTL-3PH Inverter show a GridOVP error?
    • A
      amberramirezAug 21, 2025
      If the GridOVP alarm occurs occasionally on your Sofarsolar Inverter, it might be due to temporary electric grid issues. The inverter should automatically return to normal operation once the grid stabilizes. However, if the alarm appears frequently, verify that your grid voltage and frequency are within the acceptable range. If they are, inspect the AC circuit breaker and AC wiring of the inverter. If the grid voltage/frequency is outside the acceptable range and the AC wiring is correct, contact technical support to adjust the over-voltage, under-voltage, over-frequency, and under-frequency protection settings, but only after getting approval from your local electrical grid operator.
  • T
    Timothy HarrisAug 25, 2025
    What to do if my Sofarsolar HYD 5KTL-3PH shows a BMS communication failure of lithium battery?
    • L
      laurenbairdAug 25, 2025
      If you're experiencing a BMS communication failure of the lithium battery with your Sofarsolar Inverter, first ensure that your battery is compatible with the inverter, CAN communication is recommended. Then, check the communication line and port between the battery and the inverter for any faults.
  • G
    gparkerAug 28, 2025
    How to prevent OverTempDerating on my Sofarsolar HYD 5KTL-3PH?
    • C
      Carl SnowAug 28, 2025
      To resolve OverTempDerating on your Sofarsolar Inverter, make sure the unit is installed away from direct sunlight.
  • H
    Hunter EvansSep 1, 2025
    What to do if my Sofarsolar HYD 5KTL-3PH Inverter displays TempFault_Bat?
    • L
      Lauren WilliamsSep 1, 2025
      To address a TempFault_Bat error on your Sofarsolar Inverter, ensure it is installed away from direct sunlight in a cool, well-ventilated area. Also, confirm that the inverter is mounted vertically and the ambient temperature remains below the inverter's temperature limit.
  • E
    Erica Jennings MDSep 4, 2025
    What to do if my Sofarsolar HYD 5KTL-3PH displays a GFCI error?
    • R
      Randall RichardsSep 5, 2025
      If your Sofarsolar Inverter is showing a GFCI error, it may indicate internal faults. Try switching the inverter OFF, waiting for 5 minutes, and then switching it back ON to see if the problem resolves. If not, contact technical support.
  • J
    Julie MillerSep 9, 2025
    What to do if my Sofarsolar HYD 5KTL-3PH shows FanFault1?
    • K
      Kyle SmithSep 9, 2025
      To troubleshoot FanFault1 on your Sofarsolar Inverter, check whether fan 1 is running normally.

Sofarsolar HYD 5KTL-3PH Specifications

General IconGeneral
ModelHYD 5KTL-3PH
Rated Power5000 W
Number of MPPTs2
Rated AC Power5000 W
Max. AC Current8 A
AC Frequency Range50/60 Hz
Total Harmonic Distortion (THD)<3%
European Efficiency97.5%
Protection ClassIP65
CoolingNatural convection
Max. AC Power5500 VA
Operating Temperature Range-25°C to 60°C