OPERATION OF THE DEVICE
HYD 5K...20KTL-3PH 95
Press down button again to show Battery 1 parameters
like current, power, state of charge etc.
Press down button again to show Battery 2 parameters
like current, power, state of charge etc.
7.3 Energy storage modes
The HYD 5 … 20KTL-3PH comes with several integrated energy
management modes.
7.3.1 Self-use Mode
In the Self-use mode, the inverter will automatically charge and
discharge the battery according to the following rules:
If PV generation equals the load
consumption (ΔP < 100 W), the
inverter won't charge or discharge
the battery
If PV generation is larger than the
load consumption, the surplus
power is stored in the battery
If the battery is full or at maximum
charging power, the excess power
will be exported to the grid