PRODUCT FEATURES
HYD 5K...20KTL-3PH 27
NOTE
• Configuration of the battery setup should only be done
when the inverter is in standby mode!
Advanced Settings – 10. Switch on / off – Off
• If a battery input is unused, ensure to set this in the
inverter's system settings, for example:
System Settings – Input Channel Config – Bat Channel2 –
Not Used.
• The battery inputs of different inverters should not be
connected in parallel
• Each battery tower corresponds to a unique battery
address. Each battery address can be configured from 00–
15 or not used
• The other battery parameters should be set according to
the battery specifications