SOFAR 1.1K~3.3KTL-G3 User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 59 -
board is fault
ID55
RelayTestFail
The relays fault
ID56
PvIsoFault
The insulation
resistance is too low
Check the insulation resistance between the
PV array and earth(ground), if a short circuit
occurs, rectify the fault.
ID57
OverTempFault_
Inv
The inverter temp is
too high
Ensure the installation position and
installation method meet the requirements of
Section 3.4 of this user manual.
Check whether the ambient temperature of
the installation position exceeds the upper limit.
If yes, improve ventilation to decrease the
temperature.
ID58
OverTempFault_
Boost
The Boost temp is
too high
ID59
OverTempFault_
Env
The environment
temp is too high
ID65
UnrecoverHwAc
OCP
The grid current is
too high, and has
cause unrecoverable
hardware fault
ID65-ID70 are internal faults of inverter,
turn OFF the “DC switch”, wait for 5 minutes,
then turn ON the “DC switch”. Check whether
the fault is rectified. If no, please contact
technical support.
ID66
UnrecoverBusO
VP
The bus voltage is
too high, and has
cause unrecoverable
fault
ID67
UnrecoverIacRm
sUnbalance
The grid current is
unbalance, and has
cause unrecoverable
fault
ID68
UnrecoverIpvUn
balance
The input current is
unbalance, and has
cause unrecoverable
fault
ID69
UnrecoverVbus
Unbalance
The bus voltage is
unbalance, and has
cause unrecoverable
fault
ID70
UnrecoverOCPI
nstant
The grid current is
too high, and has
cause unrecoverable
fault
ID71
UnrecoverPvCon
figSetWrong
Incorrect input
mode
Check the input mode(parallel mode/
independent mode) setting of inverter according
to Section 6.3 (C) 6.Input Mode of this user
manual, If it’s incorrect, change it according to
Section 6.3 (A) 10.Set Input mode of this manual
ID74
UnrecoverIPVIn
stant
The input current is
too high, and has
cause unrecoverable
fault
ID74-ID77 are internal faults of inverter,
turn OFF the “DC switch”, wait for 5 minutes,
then turn ON the “DC switch”. Check whether
the fault is rectified. If no, please contact
technical support.
ID75
UnrecoverWRIT
EEEPROM
The EEPROM is
unrecoverable
ID76
UnrecoverREAD
EEPROM
The EEPROM is
unrecoverable