02/2015
Initial operation
Plug the plug into the socket.
For those models without a switch or remote control, heating starts
immediately upon plugging of the plug into the socket.
Remote control
The heater type DS 02010 is equipped with a remote control; initial programming is
necessary for initial operation.
Hand-held transmitter
Switching on/off: Brief pressing of the programmed radio channel
key on the hand-held transmitter switches the
infrared heater on or off.
Short-term heating: Double-clicking on the programmed radio channel
key switches the infrared heater on for 15 minutes
and then automatically switches it off again.
Heating level: Long pressing of the programmed key on the
hand-held transmitter switches the heat output up
and down between three levels (33, 66 and 100%).
The LEDs signal the selected heat levels.
Timed switch off: If a timed switch-off has been activated in the
programming, the infrared heater always switches
off automatically after the specified time of 30 / 60 /
90 minutes. Every minute, LED 2 signals the
residual time by differentiated flashing. Each one
second flash duration indicates 15 minutes of
outstanding heating time.
Memory function: Upon switching back on, a short press of the key
recalls the last heating level.
Key allocations:
Keys 1 – 4
Radio channel keys
GB