Service Manual
Heat Pump for Heating & Cooling & DHW
Service Manual
Model:
BLN-006TB1BLN-006TD1
BLN-010TB1BLN-010TB3
BLN-014TB1BLN-014TB3
BLN-018TB1BLN-018TB3
BLN-024TB3BLN-024TD3
BLN-010TD1BLN-010TD3
BLN-014TD1BLN-014TD3
BLN-018TD1BLN-018TD3
SolarEast Heat Pump Ltd.

Table of Contents

Questions and Answers

  • H
    Hannah DavisAug 17, 2025
    What to do if my SolarEast BLN-006TD1 shows E03 water flow error?
    • A
      Ashley ParkerAug 17, 2025
      To troubleshoot a SolarEast Heat Pump experiencing an E03 error (water flow switch failure or low water flow protection), follow these steps: * Ensure the pipeline valve is fully open to allow clear water flow. * Verify the water flow switch is correctly installed and the model is appropriate. * Confirm the water flow switch connection line is inserted into the correct port (D13 white). * Check that the circulating water pump is functioning normally and the water system isn't blocked. * Assess the water pump's head and flow; if insufficient, consider adding a hot water auxiliary pump. * Ensure the external auxiliary pump is not reversed.
  • R
    Robert ChristianAug 22, 2025
    What to do if my SolarEast BLN-006TD1 Heat Pump displays E06 Low voltage switch failure?
    • L
      Lisa DawsonAug 22, 2025
      If your SolarEast Heat Pump is showing error code E06, indicating a low voltage switch failure, here are the steps you can take to resolve the issue: 1. Check the low-pressure pressure switch for any damage and ensure the wiring terminals are correctly connected (low voltage switch D12 blue). 2. Use a pressure gauge to connect to the low-pressure inspection port and measure if there is a refrigerant leak in the system. After supplementing the refrigerant, use foam to check for refrigerant leakage at the welding joint of the copper pipe. 3. Verify that the fan is operating normally. 4. Inspect the system for blockages by connecting a pressure gauge to both the high and low-pressure inspection ports simultaneously to measure whether the operating pressure of the system is normal.
  • P
    Patrick FloydAug 25, 2025
    What to do if SolarEast BLN-006TD1 shows E12 Exhaust temperature too high protection?
    • N
      Nicole ThompsonAug 26, 2025
      To address an E12 error (Exhaust temperature too high protection) on your SolarEast Heat Pump: 1. Check the system for blockages or insufficient refrigerant. Use a pressure gauge to connect to the high and low pressure inspection ports to measure the operating pressure of the system. 2. Check if the exhaust gas temperature sensor is damaged. Use a multimeter to measure the resistance value (T3 red port).
  • C
    Charles LoveAug 28, 2025
    What to do if my SolarEast BLN-006TD1 Heat Pump displays error E37?
    • D
      davidterrellAug 28, 2025
      To resolve the E37 error (Too large temperature difference between inlet and outlet water protection) on your SolarEast Heat Pump, you can take the following steps: 1. Make sure that the pipeline valve is fully open. 2. Check if the water pump is working. 3. Check the rated head of the pump and whether the rated flow meets the requirements for normal operation of the machine. 4. Manually drain the drain pump and pipe air.
  • J
    Justin JonesAug 30, 2025
    What to do if SolarEast BLN-006TD1 shows E02 Phase loss fault?
    • W
      Wesley FitzgeraldAug 31, 2025
      If your SolarEast Heat Pump displays error E02 (Phase loss fault), take these steps: 1. Ensure the power cord is securely connected. 2. Use a multimeter to check for 220V voltage between the neutral wire and each live wire while the power is on. 3. Use a multimeter to check for 380V voltage between the three live wires while the power is on. Note that 220V machines will not experience this failure.
  • Z
    zalvaradoSep 2, 2025
    How to fix SolarEast BLN-006TD1 E01 wrong phase protection?
    • T
      Tyler ClarkSep 2, 2025
      If your SolarEast Heat Pump shows E01 (wrong phase protection) error, the solution is to exchange any two of the three live wires (R, S, T) and then power on the machine again. Note that 220V machines will not have this failure.
  • D
    Deborah RamseySep 5, 2025
    What to do if my SolarEast BLN-006TD1 shows E09 Communication failure?
    • J
      jose69Sep 5, 2025
      To address an E09 error (Communication failure between the wire controller and the main board) on your SolarEast Heat Pump: 1. Check whether the communication between the wire controller and the main board is normal. 2. Use a multimeter to measure whether the voltage output of the motherboard port is normal (white port).
  • L
    Lisa MatthewsSep 8, 2025
    What to do if SolarEast Heat Pump shows E15 Inlet water temperature sensor failure?
    • C
      Christine RobertsSep 8, 2025
      To troubleshoot an E15 error (Inlet water temperature sensor failure) on your SolarEast Heat Pump, consider the following: 1. Check if the sensor connection line is open or disconnected. 2. The sensor may be damaged. 3. The motherboard port may be damaged. 4. Use a multimeter to measure whether the resistance is correct (T8 white port).
  • G
    Gregory JonesSep 12, 2025
    What to do if SolarEast BLN-006TD1 Heat Pump displays E16 Coil sensor failure?
    • L
      Lisa GreenSep 12, 2025
      To troubleshoot an E16 error (Coil sensor failure) on your SolarEast Heat Pump, you can check the following: 1. See if the sensor connection line is open or disconnected. 2. The sensor might be damaged. 3. The motherboard port could be damaged. 4. Use a multimeter to measure whether the resistance value is correct (TI red port).
  • P
    Peter KrauseSep 13, 2025
    What to do if my SolarEast BLN-006TD1 Heat Pump shows E18 Exhaust sensor failure?
    • E
      erictrujilloSep 13, 2025
      To resolve an E18 error (Exhaust sensor failure) on your SolarEast Heat Pump, check the following: 1. Ensure the sensor connection line is not open or disconnected. 2. Verify the sensor is not damaged. 3. Check that the motherboard port is not damaged. 4. Use a multimeter to measure whether the resistance is correct (TI red port).

Summary

Selection and Installation Guide

Installation Guidelines and Safety

Guidelines and warnings for safe and correct heat pump installation.

Installation Steps

Step-by-step instructions for heat pump and auxiliary pump installation.

Electrical Wiring Safety

Safety guidelines and recommendations for electrical connections.

Electrical Operation and Control

Wire Controller Operation

Guide to using the wired controller's display and buttons.

Troubleshooting Fault Codes

List of error codes, their descriptions, and troubleshooting steps.

Waterway Installation and Wiring Diagrams

Diagrams and explanations for waterway system installation and wiring.

Error Diagnosis and Troubleshooting

Troubleshooting Common Faults

Solutions and maintenance steps for common error codes.