EasyManua.ls Logo

SolaStat AlphaStat-Plus - AlphaStat-Plus Technical Specifications

SolaStat AlphaStat-Plus
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19.08-14
AlphaStat-Plus Specifications.
Power Supply.
Supply Voltage. -H 85~264Vac/dc (standard model)
-M 22~85Vdc. (Must be specified at time of ordering.)
-L 10~28Vac/dc. (Must be specified at time of ordering.)
Max power usage. 5VA + external loads.
Relay Outputs. 16A max (240Vac) Resistive with permanent wiring.
Note that 3.6kW element under certain conditions will draw over
16A. Hence we recommend using max 3kW element or external
relay.
10A (240Vac) Resistive with standard mains cable supplied.
Sensors.
Display range -20 ~ +140C
Control Range -40 ~ +150C
Stainless steel tip -40 ~ +150C; 6mm diameter x 30mm
PVC Sensor cable -40 ~ +105C; 4mm diameter, UV resistant. (Standard Models)
Teflon Sensor Cable -40 ~ +250C; 4mm diameter, UV resistant. (Special Order)
Accuracy +/-1C @ 25C
Adjustable Values Range.
Set-Off 21~75C
Set-On 20~74C
Demand: 20~100C
Biosafe: 50~70C or OFF.
EMC and Safety Compliances.
Emissions: EN 55022-A, CTick.
Immunity: EN 50082-1.
Safety Compliance: EN 60950, CTick.
General Specifications. (Unless otherwise stated in other input specifications.)
Operating Temperature: 0~60C
Operating Humidity: 90% RH Max. Non-Condensing
Enclosure Construction Polycarbonate - Impact Resistant
UL94 V-2 Non Burning, UV Stabilized
Water resistant or rear entry option available.
Dimensions L=167, W=142, H=40mm, excluding glands and cables
Weight. Standard model + sensors + packaging =
1200grams
Product Liability. This information describes our products. It does not constitute guaranteed
properties and is not intended to affirm the suitability of a product for a particular application.
Due to ongoing research and development, designs, specifications, and documentation are
subject to change without notification. Regrettably, omissions and exceptions cannot be
completely ruled out. No liability will be accepted for errors, omissions or amendments to this
specification. Technical data are always specified by their average values and are based on
Standard Calibration Units at 25C, unless otherwise specified. Each product is subject to the
‘Conditions of Sale’.