Do you have a question about the SolaX Power SK-SU3000 and is the answer not in the manual?
| Model | SK-SU3000 |
|---|---|
| Type | Hybrid Inverter |
| Rated AC Power | 3000 W |
| Max. AC Output Power | 3000 W |
| Max. AC Apparent Power | 3000 VA |
| Max. DC Power | 4500 W |
| Max. DC Input Power | 4500 W |
| Max. DC Voltage | 600 V |
| Number of MPPTs | 1 |
| Max. Input Current per MPPT | 13A |
| Output Voltage | 230 V |
| Nominal AC Voltage | 230 V |
| THDi | < 3% |
| Max. Efficiency | 97.6% |
| Euro Efficiency | 97.0% |
| Battery Voltage Range | 40-60V |
| Max. Charge/Discharge Power | 3000W |
| Protection Degree | IP65 |
| IP Rating | IP65 |
| Grid Connection | Single Phase |
| AC Voltage Range | 180V-280V |
| Max. AC Current | 13A |
| Grid Frequency | 50Hz/60Hz |
| DC Injection Current | <0.5% In |
| Power Factor | 0.8 leading - 0.8 lagging |
| Communication | CAN, RS485, WiFi |
| Operating Temperature Range | -25 °C to +60 °C |
| Cooling | Natural |
Explains the meaning of safety instructions and general information symbols.
Describes the X-hybrid system components and its EPS function.
Discusses the importance and installation of surge protection for PV installations.
Covers critical safety warnings for operation, including high voltages.
Explains symbols used in the manual and on the device for clear understanding.
Key site requirements and safety rules for installation.
Step-by-step guide for physical mounting.
Overview of system connection steps.
Steps to initiate the inverter's operation.
Lists common faults and provides diagnostic and resolution steps.
Continues listing common faults and their corresponding solutions.