M
Page 28 of 36
SOLIS Ltd
SOLIS-House
CH-8152 Glattbrugg
SOLIS MASTER TOP
6_Special Programming_M_e
12.03.01 B.K
30.08.05
Special programming functions and errror messages,
SOLIS MASTER TOP
The standard software of the SOLIS MASTER TOP integrates various special programming
functions. Please proceed as follows:
• Switch machine to stand-by
• Press and hold the selection switch mentioned below and switch on the machine with
the operating switch (1).
• Program value with the quantity selection switch, if required (5).
• Register the new program data with the programming switch (7).
Refere to page 4 of the operating manual.
Stand-by mode:
Key combinationen Programing function
3 reset counter for cleaning
7 defaults
7 + 8 Factory Preset
description: defaults: remarks:
OFF time 5 5h
pre infusion ON espresso, coffee
rinsing at ON ON
coffee volume Espresso 4
coffee volume Coffee 4
coffee volume Pot 4
temperature 4
steam boiler ON
2
grinder current 2 replacement PCB
x new machines
On factory preset, descaling indication and grinder current remains
the same.
7 + 6 Descaling indication
1- 6 LED flashes
1 = 625 coffee / ca. 100 Liter > 14 dH > 250 ppm
2 = 1325 coffee / ca. 200 Liter 13 –14 dH 232 – 250 ppm
3 = 2325 coffee / ca. 350 Liter 10 –12 dH 178 – 214 ppm
4 = 4500 coffee / ca. 600 Liter 7 – 9 dH 125 – 160 ppm
5 = 5500 coffee / ca. 750 Liter 5 – 7 dH 89 – 125 ppm
6 = (no indication)
7 + 2 Grinder current adjustment
1- 6 LED flashes
program the value indicated on the grinder label