EasyManua.ls Logo

SOLIS Master Top - Page 30

SOLIS Master Top
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M
Page 28 of 36
SOLIS Ltd
SOLIS-House
CH-8152 Glattbrugg
SOLIS MASTER TOP
6_Special Programming_M_e
12.03.01 B.K
30.08.05
Special programming functions and errror messages,
SOLIS MASTER TOP
The standard software of the SOLIS MASTER TOP integrates various special programming
functions. Please proceed as follows:
• Switch machine to stand-by
• Press and hold the selection switch mentioned below and switch on the machine with
the operating switch (1).
• Program value with the quantity selection switch, if required (5).
• Register the new program data with the programming switch (7).
Refere to page 4 of the operating manual.
Stand-by mode:
Key combinationen Programing function
3 reset counter for cleaning
7 defaults
7 + 8 Factory Preset
description: defaults: remarks:
OFF time 5 5h
pre infusion ON espresso, coffee
rinsing at ON ON
coffee volume Espresso 4
coffee volume Coffee 4
coffee volume Pot 4
temperature 4
steam boiler ON
2
grinder current 2 replacement PCB
x new machines
On factory preset, descaling indication and grinder current remains
the same.
7 + 6 Descaling indication
1- 6 LED flashes
1 = 625 coffee / ca. 100 Liter > 14 dH > 250 ppm
2 = 1325 coffee / ca. 200 Liter 13 –14 dH 232 – 250 ppm
3 = 2325 coffee / ca. 350 Liter 10 –12 dH 178 – 214 ppm
4 = 4500 coffee / ca. 600 Liter 7 – 9 dH 125 – 160 ppm
5 = 5500 coffee / ca. 750 Liter 5 – 7 dH 89 – 125 ppm
6 = (no indication)
7 + 2 Grinder current adjustment
1- 6 LED flashes
program the value indicated on the grinder label