SOLIS MASTER TOP
6_Special Programming_M_e
12.03.01 B.K
30.08.05
Key combinationen Programing function
7 + 9 Steam boiler ON / OFF
7 + 4 Switch OFF time adjustment
1- 6 LED flashes
1 = 1h
2 = 2h
3 = 3h
4 = 4h
5 = 5h
6 = switch OFF time disabled
7 + 3 Automatic rinsing ON / OFF
ON = cleaning LED on during default indication
8 + 4 Credit system mode
If credit system is installed only
8 / 2 / 9 Preinfusion ON / OFF
ON = symbol espresso
symbol Coffee
symbol pot
LED on during default indication
Machine ready:
4 + 3 Rinsing
starts a rinsing
3 x 7 Temperature program
1 – 6 corresponding LED on
value boiler temperature
1 82
2 84
3 86
4 88
5 90
6 92
Error messages:
LED Errors
+ 1 Temperature sensor coffee / water: short circuit or disconected
+ 2 Temperature sensor steam: short circuit or disconected
+ 3 Wrong position of brewing unit (micro switch)
+ 4 Broken output device of grinder or brewing unit
+ 1 Grinder blockage