17
IMPORTANT! FIRST USE:
When first using the dehumidifier, operate the unit
continuously 24 hours.
This dehumidifier is designed to operate with a
working environment between 5°C and 35°C.
If the unit has been switched off and needs to be
switched on again quickly, allow approximately three
minutes for the correct operation to resume. This
relates to a built-in safety mechanism to maximise the
appliance lifetime.
Do not connect the dehumidifier to a powerboard
or adapter, which is also being used for other
electrical appliances.
Select a suitable location, making sure you have easy
access to an electrical outlet.
Plug the unit into an electrical socket with earth
connection.
Make sure the water tank is correctly fitted otherwise
the unit will not operate properly.
Note: When the water in the tank is quite high, please be
careful when moving the appliance to avoid it spilling.
REMOVING THE COLLECTED WATER
There are two ways to remove collected water.
1. Use the internal water tank.
When the appliance is Off and the water tank is full,
the appliance will beep 8 times. The FULL indicator
light will also flash and the digital display will show P2.
When the appliance is On and the water tank reaches
it’s full capacity, the appliance will beep 8 times. The
compressor will switch off automatically, however the
fan will operate for 30 seconds to dry any water of the
condenser. The FULL indicator light will also flash and
the digital display will show P2.
Slowly and carefully remove the water tank. Grip the
left and right handles securely and carefully pull the
tank straight out ensuring that the water doesn’t spill.
Warning! Do not sit the water tank on the floor, as it’s base
is uneven and the tank will likely spill.
Empty the water tank and refit it into the appliance,
ensuring that youve dried the outside of the water
tank if any water has spilt. The water tank must
be correctly and securely fitted for the dehumidifier
to operate.
The appliance will automatically restart once the
water tank is fitted correctly.
Warning! Never drink the water collected within the
appliance. It must be disposed of.
Warning! Whilst the water tank is removed, be careful to
ensure you don’t touch any parts inside the appliance.
Never leave the appliance unattended.
2. Continuous draining.
Water can be automatically emptied into a drain (i.e.
floor drain) by attaching the unit with a water hose
(not included).
Remove the cover from the back drain hose outlet.
Attach a drain hose (13.5mm diameter) and lead it to
the floor drain or other form of suitable drainage.
Ensure that there are no kinks within the hose that will
stop the water from flowing.
Ensure that the hose is secure and that there are
no leaks. The hose must flow downwards from the
appliance to ensure that the water flows easily
(i.e. no “hills” or high points in the hose).
Note: When the continuous drain feature is not being
used, remove the drain hose from the outlet and re-fit
the plug.