GLYDEA MOTOR with RS485
Programming Guide
1
COMMUNICATION SETTINGS
4800 BAUD
8 DATA BITS
ODD PARITY
1 STOP BIT
1. Select the correct COM port.
2. Click on “RTS”, then click on CONNECT
3. Click on “Get MTR Addr.” The default address, ABCDEF, will appear if unprogrammed.
4. Under Group Addresses, Assign an address to Group 1. It should be a 6bit Hex Address. This will then become the Motor Address for
the Glydea.
5. Up to 5 Group Address can also be assigned at this time in locations 2 through 6.
6. Click on “Set”. Allow 10 seconds for data transfer between PC and Motor.
7. Click on “Get MTR Addr” and verify the motor address has been updated.
8. Click on “Get” under GROUP ADDRESSES and verify the group addresses are set correctly.
Somfy’s configuration software is located on-line at: http://www.somfy.us/Apps/SDNSoftware/ILT2-ST30-3.5.2.exe
A USB to RS485 converter is recommended (Part 9015260).
2
ASSIGN ADDRESS