11 Considerationmustbegiventotheconnectionofthe
equipmenttothesupplycircuit.Appropriate
considerationofequipmentnameplateratingsmustbe
usedwhenaddressingthisconcern.Donotoverload
thecircuit.
12 Reliablegroundingofrack‐mountedequipmentmust
bemaintained.Particularattentionmustbegivento
powersupplyconnectionsother
thandirect
connectionstothebranchcircuits,suchaspowerstrips.
13 Theincludedpowercordisapprovedforuseonlyin
specificcountriesorregions.Beforeusingapowercord,
verifythatitisratedandapprovedforuseinyour
location.
14 MinimumpowercordratingforEuropeanUnion(CE):
Certified
powersupplycordnotlighterthanlightPVC
sheathedflexiblecordaccordingtoIEC60227,
designation,orH05 VV‐ForH05VVH2‐F2,andratedfor
atleast3G0.75mm².
15 Thefollowingstatementappliesonlytorack‐installed
productsthatareGS‐Marked:Thisequipmentisnot
intended
foruseatworkplaceswithvisualdisplayunits,
inaccordancewith§2oftheGermanordinancefor
workplaceswithvisualdisplayunits.
16 Whenshippedfromthefactory ,thisSonicWallproduct
hasasinglepowersupplyinstalled.Asecondpower
supplycanbeorderedandinstalledforredundantAC
powerandadded
reliability.Whenthesecondpower
supplyisinstalled:
• Bothpowercordsmustberemovedto
disconnectACpowerfromtheunit.
• Always disconnectthepowercordsfromthe
powersupplieswheninstallingorremovingthe
powersupply.Neverinstallorremoveapower
supplywiththeACpowercordattached.
LithiumBatteryWarning
TheLithiumBatteryusedintheSonicWallinternetsecurity
appliancemaynotbereplacedbytheuser.Theappliancemust
bereturnedtoaSonicWallauthorizedservicecenterfor
replacementwiththesameorequivalenttyperecommended
bythemanufacturer.If,foranyreason,thebatteryor
SonicWallsecurityappliancemust
bedisposedof,doso
followingthebatterymanufacturer'sinstructions.
CableConnections
AllEthernetandRS232(Console)cablesaredesignedforintra‐
buildingconnectiontootherequipment.Donotconnectthese